作为中亚重要能源枢纽国家,乌兹别克斯坦正推进其电力系统的现代化转型与可再生能源并网。
额定容量 (kVA) | 额定电压及分接范围 | 联结组别 | 空载电流 (%) | 阻抗电压 (%) | 空载损耗 (kW) | 负载损耗 (kW) | ||||
|---|---|---|---|---|---|---|---|---|---|---|
| 高压 | 分接范围 | 低压 | B (100℃) | F (120℃) | H (145℃) | |||||
| 800 | 35 36 37 38.5 | ±2x2.5% ±5 | 3.15 6 6.3 10 10.5 11 | Dyn11 Yd11 Yyn0 | 0.85 | 6.0 | 2.02 | 8.87 | 9.4 | 10.0 |
| 1000 | 0.85 | 2.4 | 10.3 | 10.9 | 11.6 | |||||
| 1250 | 0.75 | 2.81 | 12.1 | 12.9 | 13.8 | |||||
| 1600 | 0.75 | 3.32 | 14.6 | 15.4 | 16.5 | |||||
| 2000 | 0.65 | 7.0 | 3.8 | 17.2 | 18.2 | 19.5 | ||||
| 2500 | 0.65 | 4.37 | 20.6 | 21.8 | 23.3 | |||||
| 3150 | 0.6 | 8.0 | 5.42 | 23.1 | 24.5 | 26.2 | ||||
| 4000 | 0.6 | 6.31 | 27.7 | 29.4 | 31.5 | |||||
| 5000 | 0.55 | 7.53 | 32.9 | 34.9 | 37.4 | |||||
| 6300 | 0.55 | 8.91 | 38.5 | 40.8 | 43.7 | |||||
| 8000 | Dyn11 Yd11 YNd11 | 0.45 | 9.0 | 10.1 | 43.4 | 46.0 | 49.3 | |||
| 10000 | 0.45 | 11.6 | 52.4 | 55.5 | 59.4 | |||||
| 12500 | 6 6.3 10 10.5 11 | 0.35 | 14.1 | 60.9 | 64.6 | 69.1 | ||||
| 16000 | 0.35 | 17.3 | 71.7 | 76.0 | 81.3 | |||||
| 20000 | 0.3 | 10.0 | 20.6 | 80.6 | 85.5 | 91.5 | ||||
| 25000 | 0.3 | 24.3 | 95.3 | 101 | 108 | |||||
额定容量 (kVA) | 额定电压及分接范围 | 联结组别 | 空载电流 (%) | 阻抗电压 (%) | 空载损耗 (kW) | 负载损耗 (kW) | ||||
|---|---|---|---|---|---|---|---|---|---|---|
| 高压 | 分接范围 | 低压 | B (100℃) | F (120℃) | H (145℃) | |||||
| 2000 | 35 36 37 38.5 | ±4x2.5% | 6 6.3 10 10.5 11 | Dyn11 Yd11 | 0.65 | 7.0 | 4.05 | 17.9 | 19.0 | 20.3 |
| 2500 | 0.65 | 4.69 | 21.3 | 22.6 | 24.2 | |||||
| 3150 | 0.60 | 8.0 | 5.67 | 24.0 | 25.4 | 27.2 | ||||
| 4000 | 0.60 | 6.64 | 28.7 | 30.4 | 32.6 | |||||
| 5000 | 0.50 | 7.85 | 34.0 | 36.1 | 38.6 | |||||
| 6300 | 0.50 | 9.27 | 39.4 | 41.8 | 44.7 | |||||
| 8000 | 0.45 | 9.0 | 10.6 | 44.8 | 47.5 | 50.8 | ||||
| 10000 | 0.45 | 12.1 | 53.9 | 57.1 | 61.2 | |||||
| 12500 | 0.35 | 14.7 | 62.7 | 66.5 | 71.1 | |||||
| 16000 | 0.35 | 18.1 | 73.8 | 78.2 | 83.7 | |||||
| 20000 | 0.30 | 10.0 | 21.4 | 83.0 | 88.0 | 94.2 | ||||
| 25000 | 0.30 | 25.2 | 98.2 | 104 | 111 | |||||
额定容量 (kVA) | 额定电压及分接范围 | 联结组别 | 空载电流 (%) | 阻抗电压 (%) | 空载损耗 (kW) | 负载损耗 (kW) | ||||
|---|---|---|---|---|---|---|---|---|---|---|
| 高压 | 分接范围 | 低压 | B (100℃) | F (120℃) | H (145℃) | |||||
| 50 | 20 22 24 | ±2.5 ±5 | 0.4 | Yyn0 Dyn11 | 1.8 | 6.0 | 0.305 | 1.16 | 1.23 | 1.31 |
| 100 | 1.6 | 0.485 | 1.87 | 1.99 | 2.13 | |||||
| 160 | 1.4 | 0.600 | 2.33 | 2.47 | 2.64 | |||||
| 200 | ±2×2.5 ±5 | 1.4 | 0.655 | 2.77 | 2.94 | 3.14 | ||||
| 250 | 1.2 | 0.755 | 3.22 | 3.42 | 3.66 | |||||
| 315 | 1.2 | 0.870 | 3.85 | 4.08 | 4.36 | |||||
| 400 | 1.0 | 1.03 | 4.65 | 4.84 | 5.18 | |||||
| 500 | 1.0 | 1.21 | 5.46 | 5.79 | 6.19 | |||||
| 630 | 0.90 | 1.37 | 6.45 | 6.84 | 7.32 | |||||
| 800 | 0.90 | 1.57 | 7.79 | 8.26 | 8.84 | |||||
| 1000 | 0.80 | 1.86 | 9.22 | 9.78 | 10.4 | |||||
| 1250 | 0.80 | 2.14 | 10.8 | 11.5 | 12.3 | |||||
| 1600 | 0.80 | 8.0 | 2.51 | 13.0 | 13.8 | 14.8 | ||||
| 2000 | 0.60 | 2.91 | 15.4 | 16.3 | 17.5 | |||||
| 2500 | 0.60 | 3.48 | 18.2 | 19.3 | 20.7 | |||||
| 2000 | 0.60 | 2.91 | 16.8 | 17.8 | 19.1 | |||||
| 2500 | 0.60 | 3.48 | 20.0 | 21.2 | 22.7 | |||||
额定容量 (kVA) | 额定电压及分接范围 | 联结组别 | 空载电流 (%) | 阻抗电压 (%) | 空载损耗 (kW) | 负载损耗 (kW) | ||||
|---|---|---|---|---|---|---|---|---|---|---|
| 高压 | 分接范围 | 低压 | B (100℃) | F (120℃) | H (145℃) | |||||
| 30 | 6 6.3 6.6 10 10.5 11 | ±2.5 ±5 | 0.4 | Yyn0 Dyn11 | 2.0 | 4.0 | 105 | 605 | 640 | 685 |
| 50 | 2.0 | 155 | 845 | 900 | 965 | |||||
| 80 | 1.5 | 210 | 1160 | 1240 | 1330 | |||||
| 100 | 1.5 | 230 | 1330 | 1415 | 1520 | |||||
| 125 | 1.3 | 270 | 1565 | 1665 | 1780 | |||||
| 160 | 1.3 | 310 | 1800 | 1915 | 2050 | |||||
| 200 | ±2×2.5 ±5 | 1.1 | 360 | 2135 | 2275 | 2440 | ||||
| 250 | 0.90 | 415 | 2330 | 2485 | 2665 | |||||
| 315 | 0.80 | 510 | 2945 | 3125 | 3355 | |||||
| 400 | 0.80 | 570 | 3375 | 3590 | 3850 | |||||
| 500 | 0.80 | 670 | 4130 | 4390 | 4705 | |||||
| 630 | 0.70 | 775 | 4975 | 5290 | 5660 | |||||
| 630 | 0.70 | 6.0~8.0 | 750 | 5050 | 5365 | 5760 | ||||
| 800 | 0.70 | 875 | 5895 | 6265 | 6715 | |||||
| 1000 | 0.70 | 6885 | 7315 | 7885 | ||||||
| 1250 | 0.70 | 1205 | 8190 | 8720 | 9335 | |||||
| 1600 | 0.70 | 1415 | 9945 | 10555 | 11320 | |||||
| 2000 | 0.60 | 1760 | 12240 | 13005 | 14005 | |||||
| 2500 | 0.60 | 2080 | 14535 | 15445 | 16605 | |||||
额定容量 (kVA) | 额定电压及分接范围 | 联结组别 | 空载电流 (%) | 阻抗电压 (%) | 空载损耗 (kW) | 负载损耗 (kW) | ||||
|---|---|---|---|---|---|---|---|---|---|---|
| 高压 | 分接范围 | 低压 | B (100℃) | F (120℃) | H (145℃) | |||||
| 1000 | 35~38.5 | ±2×2.5 ±5 | 0.4~1.14 | Dyn11 Yd11 Yyn0 | 0.85 | 6.0~14.0 | 1.4 | 8.8 | 9.4 | 10.1 |
| 1250 | 0.75 | 1.6 | 10.7 | 11.4 | 12.2 | |||||
| 1600 | 0.75 | 1.9 | 13.1 | 13.9 | 14.9 | |||||
| 2000 | 0.65 | 2.2 | 15.4 | 16.4 | 17.5 | |||||
| 2500 | 0.65 | 2.6 | 18.5 | 19.6 | 21.0 | |||||
| 3000 | 0.60 | 3.2 | 20.3 | 21.6 | 23.1 | |||||
| 3150 | 0.60 | 3.5 | 20.7 | 22.1 | 23.5 | |||||
| 4000 | 0.60 | 4.1 | 24.9 | 26.5 | 28.2 | |||||
| 4500 | 0.55 | 4.4 | 27.4 | 29.1 | 31.1 | |||||
| 5000 | 0.55 | 4.8 | 29.6 | 31.4 | 33.6 | |||||
| 6300 | 0.55 | 5.7 | 34.6 | 36.7 | 39.2 | |||||
| 8000 | Dyn11 Yd11 YNd11 | 0.45 | 6.9 | 41.7 | 44.3 | 47.3 | ||||
| 10000 | 0.45 | 8.2 | 49.0 | 52.1 | 55.7 | |||||
额定容量 (kVA) | 额定电压及分接范围 | 联结组别 | 空载电流 (%) | 阻抗电压 (%) | 空载损耗 (kW) | 负载损耗 (kW) | ||||
|---|---|---|---|---|---|---|---|---|---|---|
| 高压 | 分接范围 | 低压 | B (100℃) | F (120℃) | H (145℃) | |||||
| 500 | 10~12 | ±5 ±2×2.5% | 0.4~1.14 | Dyn11 Yyn0 | 0.80 | 4.0~10.0 | 670 | 4130 | 4390 | 4705 |
| 630 | 0.70 | 775 | 4975 | 5290 | 5660 | |||||
| 800 | 0.70 | 875 | 5895 | 6265 | 6715 | |||||
| 1000 | 0.70 | 1020 | 6885 | 7315 | 7885 | |||||
| 1250 | 0.70 | 1205 | 8190 | 8720 | 9335 | |||||
| 1600 | 0.70 | 1415 | 9945 | 10555 | 11320 | |||||
| 2000 | 0.60 | 1760 | 12240 | 13005 | 14005 | |||||
| 2500 | 0.60 | 2080 | 14535 | 15445 | 16605 | |||||
| 3150 | 0.50 | 2520 | 17950 | 19095 | 20490 | |||||
1、35kV干式无励磁调压电力变压器
2、35kV干式有载调压电力变压器
3、35kV干式三相双绕组无励磁调压新能源发电侧光伏用、风电用、储能用变压器
4、20kV干式无励磁调压配电变压器
5、10kV干式三相双绕组无励磁调压配电变压器
6、10kV干式三相双绕组无励磁调压新能源发电侧光伏用、风电用、储能用变压器